Instruments - Gas Chromatographs
Series 816 High Performance Gas Chromatograph
- Custom engineered to fit industry-specific applications
- Detectors: TCD, DID, FID, FPD (dual detector capability)
- Corrosion resistant flow systems (optional)
- Supports 10 columns/7 automated valves in single application
- Softkey keypad with four line alphanumeric display
- Six ramp oven temperature programming control
- Contact sensitive HELP function
- Run and clock time programming
- Stop watch function
- Four 24 V valve drivers
- Two 24 V low power relays
- Two 48 V contacts for external event control
- Power failure memory protection
- Dual channel analog output (1 mV, 1 V, 10 V)
- Remote diagnostic communication capability
- Two channels of single column baseline compensation
- Built-in IEEE-488 and RS-232-C communication interfaces
- Built-in diagnostics and comprehensive self-test
- Compatible with any data management system
- Electronic Pneumatic Controls for all pneumatic parameters
- Run logs record system conditions and note deviations from expected values
- Power: 120-240 V, 50-60 Hz

Request Technical Document
Request a Quote
Series 600 Temperature Programmable Gas Chromatograph
- Microprocessor controlled temperature programming (CPU: 33 MHz 80386SX)
- Processing ability: 32-bit
- Detectors: TCD, FID, PFD, or PID (dual detector capability)
- Detectors independently temperature controlled operated singularly, in series or in parallel
- RS-232 and RS-422/RS-485 communication interfaces
- Temperature programming in 1 °C increments
- Programming rate: 0.1 °C to 40 °C/min in 0.1 °C increments
- Column temperature range: ambient +5 °C to 450 °C
- Column temperature overheat protection
- Ten ramp oven temperature programming control
- Store up to 10 methods with security PIN
- Injection modes: direct packed; capillary — split/splitless; gas and liquid sample valves
- Three independently controlled injection modules maximize efficiency, accuracy, and reproducibility
- Electronic pressure programming (EPP) (optional)
- Six external events and five heated zones
- 8-line EZ-view LCD display with touch keypad user interface
- Differential flow controls
- Corrosion resistant systems available
- Power: 120-240 V, 50-60 Hz

Request Technical Document
Request a Quote
Series 590 High Purity Gas Analysis Gas Chromatograph
Each Series 590 GC is custom built to a particular application. Contact us to discuss the details or your specific requirements.
- Discharge Ionization Detector (DID) — non-selective, non-radioactive, universal and concentration dependent
- Detector sensitivity: < 10 ppb CH4
- Detector linearity: > 105
- Dynamic range of < 5 ppb to < 1% by volume
- High analytical precision: ± 1% full scale
- Output: 4-20 mA (optional); 0-1 mV
- Helium purged housing eliminates system contamination and increases system sensitivity
- Bellows type metering valves for independent flow control of column carrier gases and detector discharge gas
- Choice of standard or corrosion resistant system
- Installation: bench or 19” rack mount
- On-line monitoring and valve manipulation by software or linking workstation
- Power: 120-240 V, 50-60 Hz

Request Technical Document
Request a Quote
Series 580 Research Gas Chromatograph
- Isothermal Operation
- Detectors: TCD, FID, DID, or PID
- Direct On-Column Injection or Gas Sample Valve: packed, capillary — split/splitless
- Single or Dual Column
- Accommodates 1/8” or 1/4” o.d. metal, 6 mm glass, or capillary columns
- Column temperature range: ambient to 400 °C
- Column oven temperature protection circuit
- Readout: 3-1/2 digit LED digital display
- Independent Temperature Controls for Column Oven, Detector, Injection Ports
- On-line monitoring and valve manipulation by software or linking workstation
- Microscale Compatible: heated, threaded exit ports, (optional — TCD only)
- Signal Amplifier, x10 (TCD — optional)
- Choice of standard or corrosion resistant system
- Installation: bench or 19” rack mount
- Power: 110-220 V, 50-60 Hz

Request Technical Document
Request a Quote
Series 400 and 400-P Gas Chromatographs
- Isothermal Operation
- Detector: Thermal Conductivity Detector (TCD)
- Direct On-Column Injection or Gas Sample Valve (manual or pneumatic)
- Single or Dual Column
- Microscale Compatible: heated, threaded exit ports (optional)
- Accommodates 1/8” or ¼” o.d. metal or 6 mm glass columns
- Signal Amplifier, x10 (optional)
- Independent, Direct Set, Temperature Controls for Column Oven, Detector, Injection Ports
- Operating temperature: ambient to 300 °C
- Power: 110-220 V, 50-60 Hz

Request Technical Document
Request a Quote
Series 400MGA Medical Gas Analyzer
The GOW-MAC Series 400MGA Medical Gas Analyzer is a gas chromatograph with a thermal conductivity detector (TCD). The analyzer is expressly configured for the rapid analysis, quality control, and validation of medical gases as called for by the latest US Pharmacopeia (USP) gas assay and identity test compliance monographs. The Series 400MGA will assure your product conforms to GMP (good manufacturing practice) standards as required by 21 CFR 211.22. Complete application documentation, method development and test chromatograms are included with each instrument.Assays and Identity Tests
99.9% USP Nitrogen Assay and Identity Test for Medical N2
97.0% USP Nitrogen Assay and Identity Test for Medical N2
99.0% USP Helium Assay and Identity Test for Medical Helium
99.9% USP Carbon Dioxide Assay and Identity Test for Medical CO2
99.9% USP Nitrous Oxide Assay and Identity Test for Medical N2O
400MGA
- Isothermal Operation
- Detector: Thermal Conductivity (TCD
- Gas Sample Valves (manual or pneumatically automated
- Dual, Preconditioned Columns
- Independent, Direct Set, Temperature Controls for Column Oven and Detector
- TCD Bridge Control: Continuous Current to adjust to 300 mA
- Temperature readout: 3-½ digit LED digital meter
- Filament Protection Circuit
- Operating temperature: ambient to 300 °C
- Power: 110-220 V, 50-60 Hz
- Lung Diffusion Mixtures
- Anaerobic Gas Mixtures
- Clinical Blood Gases
- Laser Gases
Request a Quote
Series 400-GP Gas Partitioner
The Series 400-GP Gas Partitioner is specifically designed for the quantitative determination of substances which are gaseous at room temperature. These substances include respiratory gases, blast furnace and flue gases, all of the permanent gases, as well as light hydrocarbons, and head-space gases. In addition, the instrument can easily be adapted for other analyses (light hydrocarbons up to C5, H2S, and SO2) by changing the chromatographic columns.- Isothermal Operation
- Detector: Thermal Conductivity Detector (TCD)
- Direct On-Column Injection or Gas Sample Valve
- Dual Column
- Operating temperature: ambient to 400 °C
- Accommodates 1/8” or 1/4” o.d. metal or 6 mm glass columns
- Monitors CO, CO2, O2, N2, and CH4 and light hydrocarbons up to C5, H2S, and SO2
- Power: 110–220 V, 50-60 Hz

Request Technical Document
Request a Quote
Series 200 Gas Chromatograph
- The GC offers various system configurations, each dependent upon the detector chosen
- Detector: TCD, DID, FID, NPD, FPD or PID
- Injection modes: capillary — Megabore® and micropacked
- Sample introduction: gas sample valve
- Column temperature range: ambient +10 °C to 160 °C
- Installation: 19” rack
- Power: 110–220 V, 50-60 Hz

Request Technical Document
Request a Quote
Series 200DID Gas Chromatograph
Applications include, but are not limited to: Grade 6 - Electronic gases; Grade 6 – Inerts; Grade 5 - UHP Quality Gases: air, Ar, He, CO2, O2, N2, H2; high purity, stable gas mixtures for gaseous laser applications, i.e., laser surgery, drilling, welding, bar coding generation, cutting, and filter perforation; certified trace gas mixtures; basic and applied research; calibrating lab; process control.
- Corrosive and inert sample compatibility
- Mass flow controllers
- Laminar flow system with low dead volume
- VCR fittings and orbital welds at critical connections
- Sample introduction by means of pneumatically actuated gas sampling valves
- Onboard computer control of valves
- Up to (5) micro-packed, capillary or 1/8” packed columns, system dependent
- Column oven operating temperature: ambient +10 °C to 150 °C
- Up to 6 temperature zones
- Detector operating temperature: 125 °C maximum
- Vacuum fluorescence (VF) graphical display
- Communication Protocol: Serial
- Installation: 19” rack
- Power: 105 - 240 VAC, 50/60 Hz

Request Technical Document
Request a Quote
Series 110TCD Gas Chromatograph
- Independent flow control of each column
- Laminar flow system with low dead volume
- Sample introduction via pneumatically controlled automatic gas sampling valves
- Two column and one detector oven
- Independent temperature controls for column ovens and detector
- Column oven temperature range: ambient to 350 °C
- Solid state proportioning temperature control with direct digital setting
- Digital display temperature readout
- Accommodates micro-packed and 1/8” packed columns
- Built-in signal amplification
- Filament protection circuit
- 4-20 mA output
- Choice of standard or corrosion resistant system
- Communicates using most commercially available chromatography software
- Installation: 19” rack
- Power: 120-240 VAC, 50/60 Hz

Request Technical Document
Request a Quote
Series AR710 HFADD Gas Chromatograph
Applications: specialty gas manufacturers, industrial processes requiring inert argon, the electronics industry, gas separation plants, air separation plants, nuclear industry, certification of argon purity, semiconductor industry
- Analysis of trace H2, O2, N2, CH4, CO and CO2 in high purity argon (ppb)
- Sensitivity — H2: < 15 ppb; O2: < 75 ppb; N2: < 100 ppb; CH4: < 30 ppb;
CO: < 100 ppb; CO2: <100 ppb - Analytical cycle: all components < 10 minutes
- High analytical precision: ± 1% full scale
- High stability and reproducibility
- Output: 0-100 mV; 4-20 mA (optional)
- Options: automatic or manual operation modes, auto-zero
- On-line monitoring by linking workstation
- Installation: bench or 19” rack
- Power: 110-220 V, 50-60 Hz

Request Technical Document
Request a Quote